Accurex BeneCheck Uric Acid Monitoring System
Product highlights
- Easy to use and portable device
- Gives accurate and fast results
- Requires less blood for testing
₹4100
₹4100+ free shipping with
Inclusive of all taxes
1 Box
SOLD OUT
Information about Accurex BeneCheck Uric Acid Monitoring System
Accurex BeneCheck Uric Acid Monitoring System provides instant diagnosis and monitoring of gout. This uric acid tester helps in measuring uric acid in fresh capillary whole blood from the fingertips. It works on the principle of electrochemical sensor technology.
Uses:
The device is used to measure uric acid levels in the body from fresh capillary whole blood.
Product Specifications and Features:
Directions for Use:
Safety Information:
Note:
Uses:
The device is used to measure uric acid levels in the body from fresh capillary whole blood.
Product Specifications and Features:
- Test sample: Fresh capillary whole blood
- Measuring time: 15 seconds
- Measuring range: 3-20 mg/dl (0.18-1.19 mmol/L)
- Sample volume: 1 μL
- Operation temperature: 10-40 ̊C (50-104 ̊F)
- Storage and transportation condition: 4-30 ̊C (39-86 ̊F)
- Storage and transportation relative humidity: 10-90%
- Memory: 180 test results
- Battery type: One 3V (CR2032) Lithium batter
- Battery life: Approximately 1000 tests
Directions for Use:
- Wash and cleans the hands with disinfection wipes and make sure the hands are dry before testing
- Insert the lancet firmly
- Remove and save the protective cap
- Recap the lancing device and adjust penetration depth
- Take a strip and close the vial immediately
- Insert the stip
- Make sure the code number is correct
- Pull the sliding barrel till it clicks
- Press the release button to sample
- Wipe off the first drop of blood and start sampling
- Touch the blood sample with the strip
- The result will show after the countdown. Then discard the used strip to a biohazard container
- The meter will turn off automatically
- Pierce used lancet into the protective cap
- Discard the used lancet to a biohazard container
- Recap the lancet device and store
Safety Information:
- Read the user manual carefully before use
- Store in a hygienic place
- Keep out of reach of children
Note:
- Please finish the test within 5 minutes or the meter will turn off automatically
- The meter will not turn on if the wrong end or wrong side of the strip is inserted
- Do not use expired strip
- Dropping, bumping, or other violent impact will damage the meter or cause malfunction
- Do not use the meter in an environment with possible magnetic, electromagnetic, and radioactive interferences
Country of origin: India
- Authentic Products
- Great Savings
- Home Delivery