Accurex Xpress Gluco Plus Blood Glucose Monitoring System with Free 10 Strip
Product highlights
- Measures blood glucose levels
- Easy to use
- Portable device
- Battery used device
₹470₹5006% off
₹470+ free shipping with
Inclusive of all taxes
1 Box
SOLD OUT
Information about Accurex Xpress Gluco Plus Blood Glucose Monitoring System with Free 10 Strip
Accurex Xpress Gluco Plus Blood Glucose Monitoring System with Free 10 Strip
The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and clinical settings. This kit contains 1 blood glucose meter, 10 test strips, 1 multiple-lancing device, 10 sterile lancets, 1 carry pouch, 1 warranty card, a test strip insert sheet, and 1 battery (3V).
Uses:
It is mainly used to measure blood sugar levels.
Product Specifications and Features:
Directions For Use:
Safety Information:
The system is intended for use outside the body (in vitro diagnostic use only). It should be used only for self-testing blood glucose (blood sugar) and only with fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, palm, calf or thigh. The system is intended for use in the home and clinical settings. This kit contains 1 blood glucose meter, 10 test strips, 1 multiple-lancing device, 10 sterile lancets, 1 carry pouch, 1 warranty card, a test strip insert sheet, and 1 battery (3V).
Uses:
It is mainly used to measure blood sugar levels.
Product Specifications and Features:
- Blood glucose is measured by an electrical current that is produced when a blood sample mixes with the reagent (special chemicals) of the test strip
- The electrical current changes with the amount of glucose in the blood sample
- The XPRESSGLUCO+ meter measures the strength of the electrical current, calculates your blood glucose level and then displays your result in either milligram of glucose per deciliter (mg/dL) or millimoles of glucose per litre (mmol/L).
Directions For Use:
- Wash your hands in warm, soapy water. Rinse and dry completely. Warm your fingers to increase blood flow
- Remove a new test strip from the vial. Be sure to tightly replace the vial cap after removing the test strips. Insert a test strip with the contact bar end entering into the test strip slot first. Push the test strip as far as it will
- Hold the prepared lancing device firmly against the side of your fingertip. Press the release button
- If you want to do alternative site testing, please refer to the “About Alternative Site Testing (AST)” section
- Please consult your healthcare professional before obtaining blood from a site other than your fingertip
- Gently massage your finger or puncture site to obtain the required blood volume to perform the test, you need only 0.5 μL of blood sample
- Do not smear the blood sample. To obtain the best accurate result wipe off the first drop of blood and gently squeeze another drop of blood
- When the meter shows the “ ” symbol, apply blood to the opening of the absorbent channel of the test strip where it meets the narrow channel
- Blood will be drawn into the test strip. If the test strip confirmation window is full, you will hear a beep
- After the meter counts down from 5 to 1, your blood glucose test result appears along with the unit of measure, date and time. The test result is lower than the target range Test result is within the target range. The test result is higher than the target range *The default target range is 70 mg/dl to 180 mg/dl
- This blood glucose result is automatically stored in the meter memory. Turn the meter off by removing the test strip. Discard the used test strip carefully to avoid contamination
- After use, twist off the lancing device cap. Push the exposed tip of the lancet into its protective cap
- Slide the lancet ejector forward and dispose of the used lancet in an approved container
- Discard the used lancet according to your country's safety regulations
- Replace the lancing device cap
Safety Information:
- The user should not take any decision of medical relevance without first consulting his or her medical practitioner
- Call your doctor immediately if you experience symptoms that are not consistent with your blood glucose test results
- High altitudes above 3,402 meters (11,161 ft) may affect the test results
- Temperatures outside the range of 10°C to 40°C (50°F to 104°F) may affect the test results. Do not test beyond of temperature range
- Do not perform servicing and maintenance while the meter is in use
- No modification of this equipment is allowed
- Do not use this meter near cellular or cordless telephones in a call, walkie-talkies, garage door openers, radio transmitters, or other electrical or electronic equipment that are sources of electromagnetic, radiation, as these may interfere with the proper operation of the meter
Country of origin: India