Lysun LMP 101 Blood Lipid Analysis System
Product highlights
- The Blood Lipid Analysis System provides quick results
- The Blood Lipid meter can store up to 500 results and records
- The meter can be operated by charging battery
MRP₹250002% off
₹24525
Inclusive of all taxes
1 Box
Get it delivered by Saturday, 28 December
Delivering to:
122019, Gurgaon
Additional offers
Special offer: Coupon Applied! Use coupon HEALTH3 in cart.
Information about Lysun LMP 101 Blood Lipid Analysis System
Lysun LMP 101 Blood Lipid Analysis System The analyzer applies the principle of photochemistry and is used with blood lipid test strips (LPS-101, TCS-101, TGS-101, HLS-101) .The whole blood sample to be tested is added into the sample area of the strip. In the process of rapid infiltration, blood cells are filtered out or dissolved. The substrate reacts with enzymes and chemicals in the reaction layer and lead to the color change, then the color intensity is proportional to the concentration of the substance The analyzer tests the color intensity of the reaction end point at the wavelength of 620nm, the substance concentration is calculated by the reflection coefficient. When the test strip is LPS-101,with the following formula the concentration of low density lipoprotein cholesterol in (LDL) is calculated, the ratio of TC and HDL can also be calculated. LDL=TC-HDL-TG/5 (mg/dL) or LDL=TC-HDL-TG/2.2 (mmol/L).
Uses:
The analyzer applies the principle of photochemistry and is used with blood lipid test strips (LPS-101, TCS-101, TGS-101, HLS-101) The whole blood sample to be tested is added into the sample area of the strip.
Product Specifications and Features:
Directions For Use:
Use as directed on the label or as suggested by health care professionals.
Safety Information:
Uses:
The analyzer applies the principle of photochemistry and is used with blood lipid test strips (LPS-101, TCS-101, TGS-101, HLS-101) The whole blood sample to be tested is added into the sample area of the strip.
Product Specifications and Features:
- It is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), and the calculated ratio of TC/HDL and Low Density Lipoprotein Cholesterol (LDL) in capillary blood, venous whole blood, plasma and serum
- The Blood Lipid Analysis System provides results
- The Blood Lipid meter can store up to 500 results and records
- The meter can be operated by charging battery
Directions For Use:
Use as directed on the label or as suggested by health care professionals.
Safety Information:
- Misuse of electrical meter can cause electrocution, burns, fire and other hazards
- Do not place the meter in liquid, nor put it where it could fall into liquid. If the meter becomes wet, unplug it before touching it
- Use the meter only for the purpose described in the instructions for use
- Failure to use the meter in the manner specified by the manufacturer may damage the protection provided by the meter
- Do not use accessories which are not supplied or recommended by the manufacturer
- Please use the meter in a manner specified by the manufacturer, or protection may be impaired. Do not use the meter if it is not working properly or if it has suffered any damage
- Do not let the meter come into contact with surfaces which are too hot to touch
- Do not use the meter where aerosol sprays are being used or where oxygen is being administered
- Do not use the meter out of doors
- Control solution only purchased from local distributor or manufacturer
Country of origin: China
Expires on or after: Not Applicable
A licensed vendor partner from your nearest location will deliver Lysun LMP 101 Blood Lipid Analysis System. Once the pharmacy accepts your order, the details of the pharmacy will be shared with you.
Phone Number: 0124-4166666
Address: 5th Floor Tower - B of the Presidency Building, 46/4 Mehrauli Gurgaon Road, Sector 14, Gurugram, Haryana-122001, India
Expires on or after: Not Applicable
A licensed vendor partner from your nearest location will deliver Lysun LMP 101 Blood Lipid Analysis System. Once the pharmacy accepts your order, the details of the pharmacy will be shared with you.
In case of any issues, contact us
Email ID: [email protected]Phone Number: 0124-4166666
Address: 5th Floor Tower - B of the Presidency Building, 46/4 Mehrauli Gurgaon Road, Sector 14, Gurugram, Haryana-122001, India