urit 10g urine reagent strips
thumbnail
thumbnail
thumbnail
thumbnail
URIT 10G Urine Reagent Strips

URIT 10G Urine Reagent Strips

Product highlights
  • Facilitates measurement of multiple urine constituents
  • Obtains accurate results
  • Easy and safe to use
  • Portable device
MRP
1650
Inclusive of all taxes
of100 units
SOLD OUT

Additional offers

Special offer: Coupon Applied! Use coupon HEALTH3 in cart.

Information about URIT 10G Urine Reagent Strips

URIT 10G Urine Reagent Strips
URIT10G urine reagent strips provide tests for the semi-quantitative measurement of leukocytes, ketone, nitrite, urobilinogen, bilirubin, glucose, protein, specific gravity, pH, blood, ascorbic acid, microalbumin, calcium and creatinine in urine. URIT 10G urine reagent strips consist of a plastic strip affixed with reagent papers and a calibration pad. This feature facilitates the measurement of multiple urine constituents and uses for everyday diagnosis and group examinations. The calibration pad, which is not impregnated with reagents, allows instrumental correction interference from the natural colour of urine automatically and obtains accurate results.

Uses:
URIT 10G urine reagent strips provide tests for the semi-quantitative measurement of leukocytes, ketone, nitrite, urobilinogen, bilirubin, protein, glucose, specific gravity, blood and pH in urine.

Product Specifications and Features:
  • Leukocytes: The test reveals the presence of granulocyte esterases. These esterases cleave an indoxyl ester, and the indoxyl so liberated reacts with a diazonium salt to produce a violet dye. Leukocyte esterase results may be positive in the absence of observable cells if the leukocytes have lysed. Positive results may occasionally be found with random specimens from females due to contamination of the specimen by vaginal discharge. Elevated glucose concentrations (≥55mmol/L) or high specific gravity may cause decreased test results. The presence of cephalexin, cephalothin, and tetracycline may cause decreased reactivity, and high levels of the drug may cause a false negative reaction. The test area does not react with lymphocytes. Reactivity may also vary with temperature
  • Ketone: This test is based on the principle of Legal's test and is more sensitive to acetoacetic acid than to acetone. The reagent area does not react with B-hydroxybutyric acid. Some high specific gravity/low pH urines may give reactions up to and including Trace. Normal urine specimens usually yield negative results with this reagent. False positive results (Trace) may occur with highly pigmented urine specimens or those containing large amounts of levodopa metabolites
  • Nitrite: The test is based on the principle of Griess's test and is specific to nitrite. Any degree of uniform pink colour development should be interpreted as a positive. Nitrite test suggests the presence of 10' or more organisms per mL, but colour development is not proportional to the number of bacteria present. A negative result does not in itself prove that there is no significant bacteriuria. Negative results may occur when urinary tract infections are caused by organisms which do not contain reductase to convert nitrate to nitrite; when urine has not been retained in the bladder long enough (hrs - 8hrs) for reduction of nitrate to occur; or when dietary nitrate is absent, even if organisms containing reductase are present and bladder incubation is ample. Ascorbic acid concentrations of 1.4mmol/L or greater may cause false negative results with specimens containing nitrite ion concentrations of 43umol/L or less
  • Urobilinogen: This test is based on the Ehrlich reaction. This test area will detect urobilinogen in concentrations as low as 3umol/L(approximately 0.2 Ehrlich unit/dL) in urine. The reagent area may react with interfering substances known to react with Ehrlich's reagent. Excreted pigments and medicaments that have a red intrinsic colouration in an acidic medium may produce false positive results. This test is inhibited by elevated concentrations of formaldehyde. Strip reactivity increases with temperature; the optimum temperature is 22°C- 26°C. The absence of urobilinogen cannot be determined with this test
  • Bilirubin: This test is based on the coupling of bilirubin with a diazonium salt in an acid medium. Normally no bilirubin is detectable in urine by even the most sensitive methods. Even trace amounts of bilirubin are sufficiently abnormal to require further investigation, Some urine constituents (medicines, urinary indicants) may produce a yellowish or reddish discolouration of the test paper that may interfere with interpreting the result. Ascorbic acid concentrations of 1,4mmol/L or greater may cause false negatives
  • Glucose: The test is based on the specific glucose oxidase/peroxidase reaction. The test is specific for glucose. No substance excreted in urine other than glucose is known to give a positive result. Ascorbic acid of more than 1.4mmol/L and/or high ketone concentrations (8mmol/L) may cause false negatives for specimens containing small amounts of glucose (5.5mmol/L). The reactivity of the glucose test decreases as the SG of the urine increases, False positive reactions may be caused by hypochlorite or peroxide (cleaning agents). Reactivity may also vary with temperature, Protein: The test is based on the principle of the protein error of a pH indicator. The reagent area is more sensitive to albumin. An elevated pH (up to 9) may affect the test. The residues of disinfectants containing quaternary ammonium groups or chlorhexidine are present in the urine vessel maybe lead to a false positive result
  • Specific Gravity: This test contains a detergent and bromthymol blue that indicates the presence of ionic constituents in the urine by changing colour from green to yellow. The specific gravity test permits the determination of urine specific gravity between 1.005 and 1.030.
  • pH: This test contains a mixed indicator which assures a marked change in colour between pH5.0 and pH9
  • Blood: Hemoglobin and myoglobin catalyze the oxidation of the indicator utilizing organic hydroperoxide contained in the test paper. This test is highly sensitive to haemoglobin and thus complements the microscopic examination. The sensitivity of this test may be reduced in urine with high specific gravity. The test is equally sensitive to myoglobin as to haemoglobin (Hemoglobin concentration of 150 Mg/L - 520 Mg/L is approximately equivalent to 5-15 intact red blood cells per microlitre). Captopril and Lodine may also cause decreased reactivity. Blood is often found in the urine of menstruating females. Certain oxidizing contaminants, such as hypochlorite, may produce false positive results. Microbial peroxidase associated with urinary tract infection may cause a false positive reaction. Ascorbic acid concentrations of 1.4mmol/L or greater may cause false negatives at the trace levels
  • Microalbumin: The albumin's reaction is more sensitive than the reaction of globulin, haemoglobin Bence-Jones protein and mucin, thus the negative result does not rule out the existence of the above-mentioned proteins in urine. When the results are 20mg/L - 200mg/L, it is indicated as microalbuminuria, and when the results are beyond 200mp/L, it is indicated as clinical albuminuria. This action is few effects on creatinine and haemoglobin etc. A high cushion of urine and alkaline urine may cause false positive results
  • Calcium: The test is based on the calcium ion in urine reacting with OCPC to produce a colour change. A great number of magnesium ions in urine may affect the test
  • Creatinine: The test is based on the creatinine in urine reacting with 3,5-Dinitrobenzoic acid to produce a colour change. Daily creatinine excretion, related to muscle mass of the human body, is usually constant. Some compounds' physical properties and high-concentration yellow pigment may affect the test result microalbumin-to-creatinine ratio. For the MA, combining with creatinine and getting the ratio can reduce the stochastic error. Normally, the ratio is lower than 3.4mg/mmol, when the ratio is between 3.4 mg/mmol to 33.9mg/mmol, it is abnormal, and when it is beyond 33,9mg./mmol, it is highly abnormal

Directions For Use:
  • Additional materials required: URIT-50,180, 5008, 500C, 330, 31, 560 urine analyzer
  • Completely immerse the pads into fresh, well-mixed urine, and the sample tube of urine should be higher than 88mm. make sure that all pads are wetted. Remove the strip after 2 seconds. The drip method also permitted
  • While removing the strip, drag the edge of the strip against the rim of the urine container to remove excess urine. Blot the strip on the length-wise edge, on absorbent paper. Avoid running over contamination from adjacent reagent pads
  • When interpreting the result by urine analyzer, please follow the respective operating manual

Safety Information:
  • The test is intended to use by healthcare professionals
  • The strip does not apply for the visual test, labels on the colour piece are for reference only, not for test judging
  • Collect a fresh urine specimen in a clean, dry container. Do not expose urine specimens to sunlight as this induces oxidation of bilirubin and urobilinogen and hence leads to artificially lower results for these two parameters
  • No touching with hand, the reaction block of reagent strips should keep clean to avoid contamination
  • Do not remove desiccants. Replace the cap immediately and tightly after removing the reagent strip, a long time (more than 5 minutes) exposing it to moist air can easily lead to inaccurate test results
  • Do not use reagent strips after the expiry date, and do not use deteriorated, discoloured or blackened test strips
  • Return to room temperature before use
  • False-positive readings for blood and glucose can result from residues of strongly oxidizing disinfectants in the specimen collection vessel. Do not add preservatives to the urine. Avoid contamination by volatile chemicals
  • The used test strip can not be reused, but should be disposed of as general medical waste

Want to share the information?

Country of origin: India
  • icon
    Authentic Products
  • icon
    Great Savings
  • icon
    Home Delivery
Content Details
Last updated
18 Nov 2024 | 01:06 AM (IST)

We provide you with authentic, trustworthy and relevant information

Want to know more

Have issue with the content?

Report Problem

INDIA’S LARGEST HEALTHCARE PLATFORM

260m+
Visitors
31m+
Orders Delivered
1800+
Cities
Get the link to download App
Reliable

All products displayed on Tata 1mg are procured from verified and licensed pharmacies. All labs listed on the platform are accredited

Secure

Tata 1mg uses Secure Sockets Layer (SSL) 128-bit encryption and is Payment Card Industry Data Security Standard (PCI DSS) compliant

Affordable

Find affordable medicine substitutes, save up to 50% on health products, up to 80% off on lab tests and free doctor consultations.

LegitScript approved
India's only LegitScript and ISO/ IEC 27001:2022 certified online healthcare platform

Know more about Tata 1mgdownArrow

Access medical and health information

Tata 1mg provides you with medical information which is curated, written and verified by experts, accurate and trustworthy. Our experts create high-quality content about medicines, diseases, lab investigations, Over-The-Counter (OTC) health products, Ayurvedic herbs/ingredients, and alternative remedies.

Order medicines online

Get free medicine home delivery in over 1800 cities across India. You can also order Ayurvedic, Homeopathic and other Over-The-Counter (OTC) health products. Your safety is our top priority. All products displayed on Tata 1mg are procured from verified and licensed pharmacies.

Book lab tests

Book any lab tests and preventive health packages from certified labs and get tested from the comfort of your home. Enjoy free home sample collection, view reports online and consult a doctor online for free.

Consult a doctor online

Got a health query? Consult doctors online from the comfort of your home for free. Chat privately with our registered medical specialists to connect directly with verified doctors. Your privacy is guaranteed.